Spectrophotometric estimation of ambroxol hydrochloride and cetirizine hydrochloride in tablets
Main Article Content
Abstract
maxima at 243 nm, while cetirizine hydrochloride has absorbance maxima at 229 nm in glass-distilled water. The method developed involves no separation or extraction process.The proposed methods were successfully applied to the determination of ambroxol hydrochloride and cetirizine hydrochloride in tablets, with high percentage of recovery, good accuracy, and acceptable precision. Different analytical performance parameters such as linearity, precision, accuracy, limit of detection, limit of quantitation, and robustness were determined according to International Conference on Harmonization ICH Q2B guidelines. Results of analysis of formulation given as percentage of label claim ± relative standard deviation were found to be 99.27 ± 0.8083 and 102.43 ± 1.5357 for ambroxol hydrochloride and cetirizine hydrochloride respectively. Results
of recovery studies given as percentage of label claim ± relative standard deviation were found to be 99.88 ± 0.3811 and 100.36 ± 2.0480 for ambroxol hydrochloride and cetirizine hydrochloride respectively.
Downloads
Article Details
This is an Open Access article distributed under the terms of the Attribution-Noncommercial 4.0 International License [CC BY-NC 4.0], which requires that reusers give credit to the creator. It allows reusers to distribute, remix, adapt, and build upon the material in any medium or format, for noncommercial purposes only.
References
Reynolds JE, et al. Martin dale-the extra pharmacopoeia, 31st ed. London:Royal Pharmaceutical Society; 1996. p. 1062.
Reddy MN, Rao KV, Swapna M, Sankar DG, Spectrophotometric
determination of ambroxol. East Pharm 1998;48:125-6.
Indrayanto G, Handayani R, Quantitative determination of ambroxol
hydrochloride in tablets. J Pharma Biomed Anal 1993;11:781-4.
Heinanen M, Barbas C. Validation of an HPLC method for the
quantification of Ambroxol hydrochloride and benzoic acid in a syrup
as pharmaceutical form stress test for stability evaluation. J Pharma
Biomed Anal 2001;24:1005-10.
Botterblom MH, Janssen TJ, Guelen PJ. Rapid and sensitive determination of ambroxol in human plasma and urine by high-performance liquid chromatography. J Chromatogr 1987;421:211-5.
Zaater MF, Tahboub YR, Najib NM, RP-LC method for the determination
of cetirizine in serum. J Pharma Biomed Anal 2000;22:739-44.
Lakshmi K, Niraimathi V, High performance thin layer chromatographic
determination of cetirizine and ambroxol in tablets. Indian Drugs
;40:227-30.